You just had to do it- Being a Pokey

You just had to do it. Poke your wire right through the flex duct. Um… that is a no no. Let alone you now have poked a hole in you duct work you also installed the wiring in a non-compliant way. 300.22 Wiring in Ducts Not Used for Air Handling, Read more…

By Don Hester, 6 yearsApril 24, 2019 ago
Wenatchee Home Inspection

A little History on Electrical Transformers

We really do not think much about them but they are the backbone of our electrical transmission system…The Transformer. The original 1885 Stanley prototype transformer at the Berkshire Museum. Transformers are electrical equipment consisting of two or more coils of wire used to transfer electrical energy by means of a Read more…

By Don Hester, 6 yearsApril 24, 2019 ago
Wenatchee Home Inspection

Early Wiring- Knob and Tube

                            Knob and Tube creates a mixed reaction when you discuss electrical systems in homes (dwelling units). Knob and Tube was the main standard of wiring of homes in the 20’s and 30’s. These wiring systems typically Read more…

By Don Hester, 6 yearsApril 23, 2019 ago
Wenatchee Home Inspection

When you have bad support- Electrical Services

Here is a photo of an electrical service conductor support that has been leaking for many years. The plywood sheathing of the roof is starting to delaminate and lose it’s strength from repeated wetting of the sheathing.                        You can see where someone has inserted two pieces of plywood Read more…

By Don Hester, 6 yearsApril 23, 2019 ago
Wenatchee Home Inspection

Federal Pacific Electric Circuit Breaker Demystified!

By David Harsche, CMECP™ Federal Pacific Electric Circuit Breaker Demystified! FPE used dissimilar metals which creates corrosion, impedance, and excessive heat that lead to failure. (1) Improper routing of the conductor could prevent the wire to contract under a fault which can cause the breaker not to Open. In other Read more…

By Don Hester, 6 yearsApril 22, 2019 ago
chelan real estate

Home Fire Safety

Though structural fires are not on everyone’s mind it is a something we should be thinking about when such an unfortunate event occurs. Sometimes jut having a simple plan can save a life. Here is four basic steps you should take. Everyone should have plan Mark two ways out of Read more…

By Don Hester, 6 yearsApril 21, 2019 ago
chelan real estate

Electrical Panels Gone Crazy

It amazes me how often I see improper and unsafe electrical instillation. Here is an example of an electrical panel that has been installed that is a disaster waiting to happen. Let alone all the improper wiring this is a sub-panel. Then we have metal materials around this panel that Read more…

By Don Hester, 6 yearsApril 21, 2019 ago
Codes

Electrical by the Numbers

Here is a nice post from By Glenn Mathewson on Electrical Outlets https://www.finehomebuilding.com/2019/01/10/electrical-outlets-by-the-numbers?fbclid=IwAR112-Kj93DAfDUK4bi5bhSiqzNC1lILvqeIYegL6u5pQqpNOs1eJptCaTM

By Don Hester, 6 yearsApril 20, 2019 ago
chelan real estate

A leak and a Cut

Often we see many items during a Home inspection. Here is a great example in one photo. We have several issues all grouped together. First we have a plumbing leak. Small leaks can be a harbinger for for other condition such as wood rot, insects and rodents. Next, we have Read more…

By Don Hester, 6 yearsApril 20, 2019 ago
Chelan Home Inspection

Auxiliary ground rods… Time to go

Once a common practice for telephone companies was to install an auxiliary ground rod for their equipment. This has shown to be a bad practice and should be removed and the phone and/or communication systems should now be grounded/bonded to the homes main grounding electrode system or an intersytem bonding Read more…

By Don Hester, 6 yearsApril 8, 2019 ago

Posts pagination

Previous 1 … 7 8 9 … 11 Next
Email Subscription

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 1,566 other subscribers
Blogroll

Blogroll

  • NCW Home Inspections Blog
  • NCW Home Inspections, LLC on ActiveRain
  • WordPress Planet
Hours & Info
Wenatchee WA 98801
1-509-670-9572
ncwhomeinspections@gmail.com
Daily 8:00 to 7:00
  • About NCW Home Inspections
  • Commercial Building Inspections
  • Foundation Certification for Manufactured Homes
  • Home Inspection Photos from the Field
  • Photos for Classmarker
  • Reference Documents
  • Water Testing and Sampling
  • What is inspected
Hestia | Developed by ThemeIsle